<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-03 01-57-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 4/5, 34 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 2.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 9 kHz 5974 0,4520
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,8 dBr -1,25 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 1:57, 3.01.2024
RT
"Osobnost Plus - Oldrich Bures, profesor, bezpecnostni expert ..."
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 9 kHz MIN: 6 kHz % above 77 kHz: 0,4520 Acquired: 2024/01/03 1:57:51 Total samples: 5974 Equivalent time: 0:04:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,9 dBr MIN: -1,8 dBr AVE: -1,25 dBr % above 0,2 dBr: 0,0 Last value: -1,2 dBr (2024/01/03 1:57:50) 01:44 01:46 01:48 01:50 01:52 01:54 01:56 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality